Anchoring threaded rod with IPANOL CWR Gel

IPANOL CWR Gel
Cold weather, Non-Sag, Anchoring Gel

DESCRIPTION: IPANOL CWR Gel is a solvent free, 100% solids, epoxy acrylate hybrid anchoring gel. The CWR Anchoring Gel has been designed to be utilized at temperatures as low as 0° degrees and attend high early strength.

USES: IPANOL CWR GEL is ideal for anchoring of rebar, threaded rods, and epoxy coated dowels in all concrete, brick, or stone masonry.

ADVANTAGES:

  • Made in America
  • Moisture insensitive before, during and after cure.
  • Freeze thaw resistant.
  • Styrene Free
  • Suitable for use in wet or damp holes.
  • Designed for cold weather applications
  • Fast setting and strength-producing adhesive
  • Ideal for close to the edge and shallow applications
  • For use in solid and hollow masonry

PACKAGING AND YIELD:
9.3 oz ( 275 ml) single cartridges, with nozzles and extension: 12 per case
28 fl. Oz (825ml) 750 ml x 75 ml cartridge with nozzles: 12 per case

SHELF LIFE:
One year in unopened containers. Store in a cool dry place out of direct sunlight. Keep from freezing. Store material below 75°F (23°C)

LIMITATIONS:

  • Do not thin; solvents will prevent proper cure.
  • Concrete or masonry surface must be frost free.
  • Minimum age of concrete must be 3 to 7 days, depending on curing and drying conditions
  • Do not allow mixed epoxy to reside in static mixing head or mixer for more than 5 minutes or gelation and blockage may result.
  • Per NTSB safety recommendations, the use of adhesive anchors is prohibited in sustained overhead load anchoring applications.

CAUTION – FOR INDUSTRIAL USE ONLY:
Irritant to skin and eyes. • Product is a strong sensitizer. Use of safety goggles and chemical resistant gloves are recommended. Use of a NIOSH/MSHA organic vapor respirator recommended if ventilation is inadequate. Avoid breathing vapors. Avoid skin contact.
FIRST AID
EYE CONTACT: Flush immediately with water for at least 15 minutes. Contact physician immediately.
RESPIRATORY PROBLEMS: Remove person to fresh air.
SKIN CONTACT: remove any contaminated clothing. Remove epoxy immediately with a dry cloth or paper towel. Solvents should not be used as they carry the irritant into the skin. Wash skin thoroughly with soap and water.
Clean-up: Uncured material can be removed with a citrus cleaner or other approved solvent. Collect with absorbent material. Flush area with water. Dispose of in accordance with local, state, and federal disposal regulations. Cured material can only be removed mechanically. See MSDS for additional precautionary information and health hazard data.

Downloads


Technical Product sheet


Material Safety Data Sheet

For more
information please
call IPA Systems, Inc.
at 800.523.3834 or
215.425.6607

or email us at:
info@ipasystems.com